• IMA sites
  • IMAJ services
  • IMA journals
  • Follow us
  • Alternate Text Alternate Text
עמוד בית
Sun, 05.05.24

Search results


June 2015
Michal M. Amitai MD, Lisa Raviv-Zilka MD, Marjorie Hertz MD, Zippora Erlich PhD, Eli Konen MD, Shomron Ben-Horin MD and Sara Apter MD

Abstract

Background: Only a few studies have compared the accuracy of magnetic resonance enterography (MRE) and computed tomography enterography (CTE) in the diagnosis of Crohn's disease and its complications.

Objectives: To compare the sensitivity of MRE and CTE analysis in their ability to detect, sign-by-sign, 10 classical imaging signs of Crohn's disease.

Methods: The study group comprised 42 biopsy-proven Crohn's disease patients who underwent both CTE and MRE within an average period of 6 weeks. Agreement between the two modalities in detecting the 10 most significant radiological signs of CD was evaluated using the Kappa index. The sensitivity of MRE and CTE was calculated using a standard of reference composed of all the findings seen by CTE and/or MRE. We analyzed MRE and CTE sensitivity separately in two groups, according to the time interval between the examinations.

Results: Agreement between CTE and MRE was more than 70% in 8 of the 10 signs: mural thickening, phlegmon, stenosis, skip lesions, mucosal stratification, fistula, abscess, and creeping fat. The Kappa level of agreement values for CTE versus MRE varied between substantial for phlegmon and skip lesions; moderate for fistula, creeping fat, abscess and mural thickening; and fair for stenosis and dilatation. CTE detected more findings than MRE, except for creeping fat and fistula. There was no significant difference in the sensitivity of CTE and MRE in the two groups defined by the time interval (time < 1.5 and time > 1.5 months) except for detection of dilatation.

Conclusions: Almost all imaging signs of Crohn's disease were detected equally well by both modalities regardless of the time interval between examinations. We therefore consider MRE to be reliable for imaging and follow-up in patients with Crohn's disease who may need recurrent imaging.

 

March 2011
S. Shrot, E. Konen, M. Hertz and M. Amitai

Background: Assessment of small intestinal disease remains a challenge for both clinicians and radiologists. Modern magnetic resonance enterography (MRE) is a non-radiation modality that can demonstrate both intestinal wall pathologies and extraluminal lesions.

Objectives: To analyze the results of 213 MRE scans performed since 2005.

Methods: Consecutive MRE[1] scans performed in our academic medical center between December 2005 and November 2009 were reviewed for patients' demographic data, indications for the examination, and main imaging findings. The imaging findings recorded were mural changes and intraluminal filling defects; there were also mesenteric findings and extraintestinal inflammatory findings.

Results: During the study period 213 MRE scans were performed; 70% of them for proven or suspected Crohn's disease (CD) of the small bowel. Another indication was small bowel neoplasm (6% of the scans). Bowel wall thickening and enhancement were seen in 60% and 53% of MRE scans, respectively. Mesenteric involvement was found in 52% of the patients. Incidental extraintestinal findings were detected in 17% of the scans. In 22% of the scans there was no pathological finding.

Conclusions: Our 4-year clinical experience with MRE shows that this non-invasive and non-radiating modality is a powerful technique for evaluation and long-term follow-up of small bowel pathologies. The most common clinical indication was the evaluation of Crohn’s disease. With physicians’ increased awareness, the future use of MRE in the evaluation of other small bowel pathologies such as neoplasm and celiac disease will increase.






[1] MRE = magnetic resonance enterography



 
Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
© All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel